False-Positive Axillary Lymph Nodes on FDG PET/CT Resulting From COVID-19 Immunization
; Searle, Julie ; Hopkins, Richard ;
Searle, Julie
Hopkins, Richard
Glos Author
Date
2021-12-01
Journal Title
Subject
Type
Journal Article
Collections
Files
Abstract
World-wide mass COVID-19 vaccination has been deployed starting with those most vulnerable, including the elderly and cancer patients. A 70-year-old man with right lung cancer underwent staging FDG PET/CT, which demonstrated an avid right lung mass with avid hilar and mediastinal nodes. Avid left axillary nodes of benign configuration were also noted. The patient had the Oxford-AstraZeneca COVID-19 vaccination in the left arm a week earlier. On reflection, the axillary nodes were concluded to be reactive related to this. This is a potential COVID-19 vaccination associated pitfall on PET/CT that should be considered when interpreting FDG PET/CT images.
Citation
Nawwar, A. A., Searle, J., Hopkins, R., & Lyburn, I. D. (2021). False-Positive Axillary Lymph Nodes on FDG PET/CT Resulting From COVID-19 Immunization. Clinical nuclear medicine, 46(12), 1004–1005. https://doi.org/10.1097/RLU.0000000000003657